1.
Braz. J. Anesth. (Impr.) ; 73(4): 418-425, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1447610

RESUMO

Abstract Background Robotic-Assisted Hysterectomies (RAH) require Trendelenburg positioning and pneumoperitoneum, which further accentuate alteration in respiratory mechanics induced by general anesthesia. The role of Recruitment Maneuver (RM) as a lung-protective strategy during intraoperative surgical settings has not been much studied. We planned this study to evaluate the effect of RM on perioperative oxygenation and postoperative spirometry using PaO2/FiO2 and FEV1/FVC, respectively in patients undergoing RAH. Methods Sixty-six ASA I‒II female patients scheduled for elective RAH were randomized into group R (recruitment maneuver, n = 33) or group C (control, n = 33). Portable spirometry was done one day before surgery. Patients were induced with general anesthesia, and mechanical ventilation started with volume control mode, with Tidal Volume (TV) of 6-8 mL.kg−1, Respiratory Rate (RR) of 12 min, inspiratory-expiratory ratio (I: E ratio) of 1:2, FiO2 of 0.4, and Positive End-Expiratory Pressure (PEEP) of 5 cmH2O. Patients in group R received recruitment maneuvers of 30 cmH2O every 30 minutes following tracheal intubation. The primary objectives were comparison of oxygenation and ventilation between two groups intraoperatively and portable spirometry postoperatively. Postoperative pulmonary complications, like desaturation, pulmonary edema, pneumonia, were monitored. Results Patients who received RM had significantly higher PaO2 (mmHg) (203.2+-24.3 vs. 167.8+-27.3, p < 0.001) at T2 (30 min after the pneumoperitoneum). However, there was no significant difference in portable spirometry between the groups in the postoperative period (FVC, 1.40 ± 0.5 L vs. 1.32 ± 0.46 L, p= 0.55). Conclusion This study concluded that intraoperative recruitment did not prevent deterioration of postoperative spirometry values; however, it led to improved oxygenation intraoperatively.


Assuntos
Humanos , Feminino , Pneumoperitônio/complicações , Procedimentos Cirúrgicos Robóticos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Período Pós-Operatório , Método Simples-Cego , Volume de Ventilação Pulmonar , Histerectomia/efeitos adversos , Pulmão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA